Sources
Every number and every rule on this page is cited here. Reviewed September 17, 2026.
- 24 CFR 100.205, Design and Construction RequirementsCode of Federal Regulations, U.S. Government Publishing Office, 2023The Fair Housing rule: covered multifamily dwellings for first occupancy after March 13, 1991 must have at least one building entrance on an accessible route unless impractical because of terrain, with the burden of proof on the designer and builder.
- 2010 ADA Standards for Accessible DesignU.S. Department of Justice, Civil Rights Division, 2010Section 403.3, running slope not steeper than 1:20 and cross slope not steeper than 1:48; Section 405.2, ramps not steeper than 1:12.
- Fastest-Growing Cities Are Increasingly in the South and West (Vintage 2024 Population Estimates)U.S. Census Bureau, 2025Princeton's growth from roughly 17,000 in 2020 to 37,019 by July 1, 2024, and the one-year growth of Anna, Fate and Melissa.
- Official Series Description: Houston BlackUSDA Natural Resources Conservation ServiceDrainage class moderately well and permeability class very slow, on the Blackland Prairie.
- Tex-124-E, Potential Vertical Rise of Natural Subgrade SoilsTexas Department of Transportation, Materials and Tests Division, 2017The potential vertical rise estimate a geotechnical report expresses for the soil below a building foundation.
- Stormwater General Permit for Construction Activities (TPDES General Permit TXR150000)Texas Commission on Environmental QualityCoverage by acreage disturbed, including sites that are part of a larger common plan of development, and the SWP3 required before construction begins.
- Texas SIP: 30 TAC 101.4, Nuisance (General Air Quality Rules)U.S. Environmental Protection AgencyThe Texas nuisance rule that governs dust reaching occupied buildings.
- 29 CFR 1926.651, Specific Excavation RequirementsCode of Federal Regulations, U.S. Government Publishing Office, 2023Paragraph (i), support systems where an excavation endangers an adjoining building or wall; paragraph (k), daily inspection by a competent person.
- ASTM D698, Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-lbf/ft3)ASTM InternationalThe compaction curve and maximum dry unit weight each pad's fill is measured against.
- ASTM D6938, Standard Test Methods for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth)ASTM InternationalThe nuclear gauge test used for acceptance of pad fill and utility backfill.
- Integrated Stormwater Management (iSWM) Program for Construction and DevelopmentNorth Central Texas Council of GovernmentsThe regional stormwater criteria a multifamily site's detention is drawn to.
- FEMA Flood Map Service CenterFederal Emergency Management AgencyThe official public source for flood hazard information, read before the phasing is set.

